
The wall system
A wall system designed to breathe.
The Foreverbreathe™ Wall System brings compatible, vapour-permeable materials together in one complete assembly, designed to manage moisture through the building envelope while supporting comfort, durability and a healthier indoor environment.
Inside the wall
Seven layers. One complete wall system.
The Foreverbreathe™ Wall System brings each layer of the wall together as one considered assembly. From the exterior cladding through to the interior finish, every material has a role in managing moisture, supporting thermal performance and allowing the wall to breathe.

Why it's different
See what changes when the whole system is designed to work together
When the Build Insite team came over from Australia, they spent time on Foreverbreathe™ builds with Premium Homes and Whio Homes, following the system from installation through to the finished assembly.
What stood out wasn’t one individual product. It was how the whole specification comes together on site: the order materials are installed, where airtightness is created, how the cavity is ventilated, how moisture is managed and how each layer connects to the next.
The videos below take a closer look at the details they stopped to explore and why they matter to the performance of the finished home.
Different materials. Different details. One system designed to work together.
The Wall System in Action.
Framing
Usually
Frames stood up in the weather, then dried out before close-up.
The frame is dry before it's stood up
A wall can't be closed up until the timber passes a moisture test and the certifier signs it off. That's a floor, not a target. The real work is in not getting the frame wet in the first place.
At Whio Homes the frames go together under cover, so the timber isn't taking rain and dew between stages, and the underfloor insulation is wool, which moves moisture on rather than sitting wet in the joists. A frame that went up dry and stayed dry passes without anyone waiting on it.
Whio Homes Walkthrough
Air barrier
Usually
A synthetic wrap, stapled to the frame and taped.
A board where most walls have a wrap
Magnum Board on the outside of the frame is the airtight line and the bracing element at the same time.
Being a board rather than a wrap matters on site: it doesn't sag, flap or tear, and it gives the cavity battens something solid to fix to. Every seam is taped. Vapour still moves through it — that's the whole point of the specification — but air doesn't, and neither does water.

Insulation
Usually
Gloves, long sleeves and a mask, and a shower at the end of it.
Insulation the crew handles bare-handed
Buffers temperature
Taking moisture up and giving it back moves energy with it, so the wall behaves like thermal mass and flattens the peaks at either end of the day.
Doesn't slump
Scales on the fibre surface hook together and hold the loft, so the batt is still the thickness it was fitted at in twenty years.
Quieter
Wool is a genuinely good acoustic absorber, through walls, floors and ceilings.
Binds formaldehyde
Wool molecules bond with formaldehyde in the air irreversibly. It doesn't get released again later.
How it's made
A stack of wool over a metre high goes in one end of the line and a 90mm batt comes out the other.
The wool is laid onto a conveyor in layers, folded back and forth until the depth is there, compressed, then set in an oven at 150°C. The polyester through the blend binds the fibres and holds the batt at whatever thickness the oven is set to — this run is 90mm at R2.4. That oven is the reason it doesn't slump in the wall ten years later.
Terra Lana Factory
How it goes in
No airborne fibre, no itch, no protective gear. The crew had been cutting it all morning and there was nothing floating around.
It still smells like wool because there's nothing else in it. And with Magnum Board on both faces of the frame, vapour keeps moving through the assembly rather than collecting inside it — the wool holds moisture temporarily and gives it up again, which is what keeps the R-value doing what it says.
Wool Install
What a home puts into the air
| Cooking3.0 per day | 3 |
|---|---|
| Clothes washing0.5 per day | 0.5 |
| Showers and baths1.5 per day, per person | 7.5 |
| Dishes1.0 per day | 1 |
| Breathing, active0.2 per hour, per person | 5 |
| Breathing, asleep0.02 per hour, per person | 0.8 |
| Perspiration0.03 per hour | 2 |
| Total | 20 litres |
What the wool in it can hold
| CeilingR3.6 × 150m² · 2600 GSM | 390 kg |
|---|---|
| WallR2.4 × 100m² · 2500 GSM | 250 kg |
| UnderfloorR1.8 × 150m² · 1350 GSM | 202.5 kg |
| Total | 842.5 kg |
That wool can take up 33.7 litres of water before it stops absorbing — more than a five-person home puts into the air in a day.
At 4% of dry weight. Every litre absorbed or evaporated moves 0.628 kWh, so 33.7 litres is 21.2 kWh — about what a kilogram of dry wool gives off as heat in saturated air, eight hours of an electric blanket.
Lining
Usually
Plasterboard, hung by a different trade after the carpenters leave.
The same board goes on the inside
At lining stage. Magnum Board goes up on the inside of the frame as well, ready to be stopped, so one material is doing the airtight work outside and the lining work inside.
The window frames are built to sit in the insulation line and arrive from the factory that way, so there are no reveals or extra bits of cladding added outside to make them work.
The part a builder notices: one carpentry crew carries the run from framing through to hanging boards. Fewer trades, fewer handovers, fewer places for the detail to go wrong.
Premium Homes Show Home Walk Through
Openings
Usually
A head flashing bent up on site and fitted over the window.
A head flashing that isn't a flashing
A detail worth slowing down for, because junctions are where assemblies usually fail.
The head flashing is powder-coated aluminium matched to the frame, and the extrusion is moulded as part of the window so it laps out over the cladding. The cladding tucks up underneath and there's nothing to flash afterwards — one piece, no joins in it. The fixing fin is still back on the timber frame doing its usual job, and the glass sits close to the insulation line without the cladding standing proud of the frame.
Head flashing
Finishes
Usually
Whatever paint the client picks off the chart.
The paint is part of the specification
A breathable wall finished with the wrong paint isn't a breathable wall.
The interior paint is the last layer to go on and the one most likely to seal in everything the layers beneath it were chosen to let through. Foreverbreathe paints are vapour permeable, so the assembly stays open all the way to the room.

Ready to build?
Seen how it goes together?
Our accredited builders have already built with the complete specification. See who they are, the homes they've built and how they work.
Mon–Fri 8am–5pm
